Ultrasonic Cement Strength Analyzer

 Ultrasonic Cement Strength Analyzer 

TG-4265 Ultrasonic Cement Analyzer (UCA) is an instrument that measures the compressive strength of API cement under high temperature and high pressure conditions. The instrument measures the velocity of sound through the sample then relates this value to the compressive strength using proprietary algorithms.

After the internal electronics measure the acoustic transit time, the value is transmitted to the I/O board located on the rear of the autoclave. The I/O board is connected to the RS-232 serial communication port located on the rear of the PC or to another autoclave I/O board by a four-wire RS-485 communication cable.


Product Description


       Ultrasonic Cement Strength Analyzer 

                               Model: TG-4265

Ultrasonic Cement Analyzer (UCA) is an instrument that measures the 
compressive strength of API cement under high temperature and high pressure conditions. The instrument measures the velocity of sound through the sample then relates this value to the compressive strength using proprietary algorithms.

After the internal electronics measure the acoustic transit time, the value is transmitted to the I/O board located on the rear of the autoclave. The I/O board is connected to the RS-232 serial communication port located on the rear of the PC or to another autoclave I/O board by a four-wire RS-485 communication cable.

 

Features

The major features of TG-4265 Ultrasonic Cement Analyzer (UCA) are listed below:

*Easy to install and use.

*Uses TG-5270 Data Acquisition System for data retrieval, analysis and storage.

*Tests stored in database may be sorted and retrieved based on user specified data base fields.

*Built-in pump and relief valve for sample pressure control.

*Optional external chiller system.


Benefits

Non-destructive method determining relative compressive strength.

A single sample is used to gather any desired number of data points for specific test conditions. Embedded controller for temperature control.

*  Display of current strength, transit time and temperature measurements on each cell.

*  Data Acquisition System provided for PC based database of test results.

*  Pressure control maintained with relief valve.

*  Date retained during power outages.

Heating /cooling jacket.

*  Multiple user selectable alarm settings.

*  Max. curing temperature 204℃(400°F)

*  Max. curing pressure 138MPa(20,000psi)

Utilities Required

Power: 210-230 VAC, 50/60 Hz, 15A Heater/solenoid valves

Water: Clean pressurizing water, 02 – 0.6 MPa

 Coolant: Clean water  

Air: Clean, dry compressed air; 0.5-0.8MPa

Drain: Suitable for hot water